TORNEX

Verified in numbers.

Licensed by the Ministry of Environment as a measurement agency, we issue official, legally admissible reports. We measure all three tracks—absorption, blocking, masking—with Class 1 instruments and standardized procedures, returning reports usable as-is for occupancy approvals, dispute resolution, and certification submissions.

Verified in
Solution tracks
3트랙
Absorb · Block · Mask — measured
License
1
Ministry of Environment registered (legally admissible)
Equipment
Class 1
B&K 2270 · NTi XL2 · Dirac
Lead time
3영업일
after on-site measurement
Process

Process flow.

Five steps from site survey to report issuance. Large spaces: two engineers, one day. Smaller spaces: half a day.

Step · 01

Site survey · point selection

Based on the floor plan, we select measurement points (3–12) and source positions.
0.5 영업일
Step · 02

Calibration · setup

After Pistonphone calibration of the Class 1 microphone and signal-chain checks, we begin measurement.
현장 · 30분
Step · 03

Per-track standardized measurement

We measure all three tracks—absorption (RT60·EDT·STI), blocking (D_nT,w · L'_nT,w), masking (SPL · NC)—using the procedures of ISO 3382, ISO 16283, ASTM E1573, and other applicable standards.
현장 · 3–6h
Step · 04

Data analysis

In Dirac and Artemis, we compute per-octave results and judge against the applicable guideline.
1 영업일
Step · 05

Report issuance

We return the official report (PDF and printed copies) with measurement-agency seal and engineer signature.
1 영업일
Solutions

Measure: Absorb · Block · Mask.

We measure all three tracks with standardized procedures and issue legally admissible reports.

Track 01 · Absorb

흡음 측정

From impulse responses, we measure RT60 (reverberation), EDT, C50, STI, and D50 in octave bands. With B&K 2270 + Dirac 10.5, we collect data from 3–12 seat positions and return the results alongside the guideline-based judgment. *Issued in compliance with KS F ISO 3382-2 (typical rooms), 3382-3 (open-plan offices), the School Health Act, or whichever standard the project requires.*
RT60 · EDT · STIB&K + Dirac
Track 02 · Block

차음 측정

We measure in-situ isolation performance of walls, doors, and floors (D_nT,w · R'_w), impact noise ratings (L'_nT,w), and external SPL ingress. The procedure uses NTi XL2 with an artificial sound source and a tapping machine. *Issued in compliance with KS F ISO 16283-1/2 (in-situ isolation), the Environmental Testing and Inspection Act, or whichever standard the project requires.*
D_nT,w · R'_w · L'_nT,wNTi + Impact
Track 03 · Mask

마스킹 · 배경음 측정

After masking-system commissioning, we measure SPL distribution uniformity and the 1/3-octave spectrum, and evaluate background noise (NC · Leq · LMax). For open-plan offices, we also compute speech-privacy metrics: DA · rD · LpA,S,4m. *Issued in compliance with ASTM E1573 (masking), KS F ISO 3382-3 (open-plan offices), or whichever standard the project requires.*
SPL · NC · DA · rDASTM E1573
Deliverables

Report structure.

The legally admissible official report and the technical analysis report are delivered separately.

Official report
Measurement-agency seal · engineer signature · PDF + three printed copies
Summary
Measurements · guideline comparison · pass/fail judgment
Spectrum
125 Hz – 4 kHz RT60 · SPL · NC by octave
Point map
Measurement point layout · instrument and source positions
Raw data
Impulse-response WAV · octave-band CSV · Dirac project
Recommendation
If improvement is needed: a remediation plan and material proposal
Formats
PDF (report and analysis) · CSV (raw) · WAV (impulse)
Lead time
3 business days after on-site measurement · 48h on rush
When

When to engage.

Measurement can be requested anytime documentary proof is needed—before or after occupancy, during disputes, or for certification.

✓ 적합한 시점
  • Occupancy approvals · School Health Act · dormitory regulations
  • Pre-opening tuning for performance venues and offices
  • Certification submissions — LEED, WELL, G-SEED
  • Noise complaints and floor-impact dispute resolution
  • Verification against the simulated values from prediction
⚠ 측정만으로 부족한 경우
  • During construction, when finishes are incomplete
  • Movable partitions or fluctuating occupancy — conditions must be fixed first
  • For preventive improvement, pair with the design stage
  • When audience presence affects results — agree on the test condition first

Start with the site.

Share the address and purpose of measurement—we'll return schedule, lead time, and quote within 48 hours.